Sign In | Join Free | My burrillandco.com
Home > Digital Smart Multimeter >

1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter

    Buy cheap 1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter from wholesalers
     
    Buy cheap 1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter from wholesalers
    • Buy cheap 1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter from wholesalers
    • Buy cheap 1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter from wholesalers
    • Buy cheap 1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter from wholesalers
    • Buy cheap 1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter from wholesalers

    1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter

    Ask Lasest Price
    Brand Name : CHX
    Model Number : CHX-DM032
    Certification : CE, RoHS
    Price : Negotiation
    Payment Terms : T/T, Western Union,Paypal, L/C
    Supply Ability : 50000pcs/month
    Delivery Time : 5-35days
    • Product Details
    • Company Profile

    1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter

    1000V DC 0.01V 600V AC 19999 Counts Electrical Digital Multimeter True RMS Voltage Meter


    Technical indicators


    Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
    3.2.1 True rms zero input
    3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
    3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
    3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.



    3.2.2 DC voltage

    RangeResolutionAccuracy
    10V0.001V±(0.5% of reading + 5 words)
    100V0.01V
    1000V0.1V±(0.8% of reading + 5 words)

    - Input impedance: 10MΩ
    - Maximum input voltage: 600V DC or 600V AC (rms)
    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.


    3.2.3 AC voltage

    RangeResolutionAccuracy
    6V0.001V±(0.8% of reading + 3words)
    60V0.01V
    600V0.1V±(1.0% of reading + 10words)

    - Input impedance: 10MΩ

    - Maximum input voltage: 600V AC (RMS) or 600V DC

    - Frequency range: 40 ~ 1000Hz True RMS

    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.



    3.2.4 Alternating current

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.5% of reading +10words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    6A0.001A±(2.5% of reading +10words)
    20A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    20A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
    - Frequency response: 40Hz ~ 1000Hz True RMS.

    3.2.5 DC

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.0% of reading +5words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    10A0.001A±(2.0% of reading +10words)
    20A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    10A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.


    3.2.6 Frequency

    RangeResolutionAccuracy
    9.999Hz0.001Hz±(1.0% of reading +3words)
    99.99Hz0.01Hz
    999.9Hz0.1Hz
    9.999kHz0.001kHz
    99.99KHZ0.01kHZ
    999.9KHZ0.1KHZ
    9.999MHZ0.001MHZ

    - Overload protection: 250V DC or AC (rms)
    - Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)


    3.2.7 Duty cycle

    RangeResolutionAccuracy
    0.1 – 99.9%0.1%± 3.0%

    - Frequency response: 10 ~ 10MHz

    - Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

    - Maximum input voltage: 250V AC (rms)

    Portable & Compact Design.
    Data retention.
    Low voltage symbol display.
    Background light function.
    Overload protectio n.
    Pass measurement.
    Diode: Yes
    Audion: Yes
    Pass-through measurement: Yes
    Data retention: Yes
    Background light: Yes


    Quality 1000V DC 0.01V 600V AC Electrical Digital Multimeter True RMS Voltage Meter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)