Sign In | Join Free | My burrillandco.com
Home > Handheld Digital Multimeter >

6MW 60MW Digital Display Multimeter 10MΩ Input Impedance

    Buy cheap 6MW 60MW Digital Display Multimeter 10MΩ Input Impedance from wholesalers
     
    Buy cheap 6MW 60MW Digital Display Multimeter 10MΩ Input Impedance from wholesalers
    • Buy cheap 6MW 60MW Digital Display Multimeter 10MΩ Input Impedance from wholesalers
    • Buy cheap 6MW 60MW Digital Display Multimeter 10MΩ Input Impedance from wholesalers

    6MW 60MW Digital Display Multimeter 10MΩ Input Impedance

    Ask Lasest Price
    Brand Name : CHX
    Model Number : CHX-DM036
    Certification : CE, RoHS
    Price : Negotiation
    Payment Terms : T/T, Western Union,Paypal,L/C
    Supply Ability : 50000pcs/month
    Delivery Time : 5-35days
    • Product Details
    • Company Profile

    6MW 60MW Digital Display Multimeter 10MΩ Input Impedance


    Hot Sale Digital Indicator Wind Speed Meter Anemometer Wind Speed Alarm


    Follow the steps below to replace the battery


    1) Turn off the instrument power supply.

    2) Remove all test leads from the input socket.

    3) Unscrew the captive screws of the battery cover and remove it.

    4) Remove the battery cover.

    5) Replace the new 6F22 9V battery

    6) Install the battery cover as it is, tighten the screws.


    Product warranty instructions


    Product certification is your instrument in the use of failure, seeking repair services must have, and then you purchase the invoice at the same time to be effective.

    1) When your multimeter in use fails, please contact our maintenance department as soon as possible, consultation, so as not to delay your use and warranty period.

    2) The product of the Company from the date of purchase from the warranty service. In the event of failure during the warranty period, the company professionals to confirm the reasons for the failure of non-users, the company free warranty service.

    3) If the warranty period is exceeded, the cost will be charged (repair fee + component fee).

    4) Even during the warranty period, maintenance fees are charged in the following cases.


    Technical indicators

    Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
    3.2.1 True rms zero input
    3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
    3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
    3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.


    3.2.2 DC voltage

    RangeResolutionAccuracy
    6V0.001V±(0.5% of reading + 5 words)
    60V0.01V
    600V0.1V±(0.8% of reading + 5 words)

    - Input impedance: 10MΩ
    - Maximum input voltage: 600V DC or 600V AC (rms)
    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.


    3.2.3 AC voltage

    RangeResolutionAccuracy
    6V0.001V±(0.8% of reading + 3words)
    60V0.01V
    600V0.1V±(1.0% of reading + 10words)

    - Input impedance: 10MΩ

    - Maximum input voltage: 600V AC (RMS) or 600V DC

    - Frequency range: 40 ~ 1000Hz True RMS

    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.



    3.2.4 Alternating current

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.5% of reading +10words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    6A0.001A±(2.5% of reading +10words)
    10A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    10A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
    - Frequency response: 40Hz ~ 1000Hz True RMS.

    3.2.5 DC

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.0% of reading +5words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    6A0.001A±(2.0% of reading +10words)
    10A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    10A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.


    3.2.6 Frequency

    RangeResolutionAccuracy
    9.999Hz0.001Hz±(1.0% of reading +3words)
    99.99Hz0.01Hz
    999.9Hz0.1Hz
    9.999kHz0.001kHz
    99.99KHZ0.01kHZ
    999.9KHZ0.1KHZ
    9.999MHZ0.001MHZ

    - Overload protection: 250V DC or AC (rms)
    - Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)


    3.2.7 Duty cycle

    RangeResolutionAccuracy
    0.1 – 99.9%0.1%± 3.0%

    - Frequency response: 10 ~ 10MHz

    - Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

    - Maximum input voltage: 250V AC (rms)

    Resistance

    RangeResolutionAccuracy
    600W0.1W±(0.8% of reading +3words)
    6kW0.001kW
    60kW0.01kW
    600kW0.1kW
    6MW0.001MW±(1.2% of reading +3words)
    60MW0.01MW

    - Open circuit voltage: approx. 1.0V
    - Overload protection: 250V DC or AC (rms)


    Temperature test


    RangeAccuracyResolution
    -20℃-300℃±(1.0%+4d)1℃
    301℃-1000℃±(1.9%+5d)1℃
    -4℉-600℉±(1.2%+6d)1℉
    601℉-1832℉±(1.9%+6d)1℉

    - Overload protection: 250V DC or AC (rms)